Fire-Rated Wall Assemblies. LP ® FlameBlock ® Fire-Rated OSB Sheathing is a component of the following code-compliant fire-rated assemblies. 2-Hour Exterior Wall Assembly - UL Design No. V337. 2-Hour Interior Wall Assembly - UL Design No. U350.SHAFT WALL. adjacent to wet or common areas.NOTES: (A) To achieve an FRL of -/120/120 for wall heights up to 3.3m use 13mm Fyrchek, or Fyrchek MR
Learn MoreWall Assemblies; All Courses. Contact. Where to Buy Search. X. Brands Applications Resources About Us Contact Where to Buy. Interior Wall and Ceiling. Roof. Specialty. Sub-Floor. Benefits. Building Envelope. Ease-of-Use. Energy Efficient. Fire Rated. Fire Resistant. Hail Resistant. High Impact Resistant.
Learn MoreJun 23, · UL design G586 can span 8’-0” from wall to wall or indefinitely when used in conjunction with the hanger assembly. For 1-hour assemblies , National Gypsum developed UL design I504 , which is a 1-hour horizontal assembly that consists of 3-5/8” steel studs 16” o.c. with three layers of 5/8” Type X gypsum board applied to the underside .
Learn Moreul design no. u415 b notes: stud and insulation sizes are minimum unless otherwise stated in design. for the most up -to -date information or assembly options, refer to the ul fire resistance directory. refer to the ul fire resistance directory for information regarding product orientation and fastening requirements. gypsum board: steel studs:
Learn MoreFace Layers: 1/2" FLAME CURB® Super C, applied parallel to studs with vertical joints midway between studs and laminated to Shaftliner panel with 4" wide strips of taping compound at wallboard perimeter and vertical centerline. 1‐ 1/2" type G drywall screws 24"o.c. located 1‐1/2" back from wallboard edges and at vertical centerline.
Learn MoreUL U415 System B — Shaft Wall, Steel Stud (Non-Load-Bearing) Products Products > Pipe Insulation. Batts. Pipe and Tank . Blown-in Insulation. Board. Rolls. UL Assemblies / Wall / UL
Learn MoreIt provides you with a choice and peace of mind knowing you’re using a tested and approved assembly. Shaftwall System consists of 1" shaftliner panels supported by 2-1/2", 4" or 6" C-T Studs and faced on one side with two layers of 1/2" fire code board. Stairwall Systems are designed to enclose stairwalls, this system is finished on both
Learn MoreUL U415 System C Shaft Wall, Steel Stud (Non-Load-Bearing) Stc 51 Fire Rating 2 Hour System Thickness 4-3/4" PDF (272.60 KB PDF) REVIT (1.98 MB RVT) CAD (48.25 KB DWG) Assembly Details Gypsum Board 1" thick Gypsum Liner Panel (UL Type SLX) Steel Studs 4" thick CH Studs, 20ga. MSG., Spaced 24" O.C. Insulation 3" thick Mineral Wool Insulation
Learn MoreThe horizontal joints should be offset from any splice joints in the shaftliner panels by at least 12" (305 mm). Install the face layer vertically with 1-5/8" (41 mm) Type S or S-12 screws spaced 12" (305 mm) o.c. starting 6" (152 mm) from top and bottom.
Learn MoreOnly products which bear UL's Mark are considered Certified. Fire-resistance Ratings - ANSI/UL 263 See General Information for Fire-resistance Ratings - ANSI/UL 263 Design No. U465 June 07, Nonbearing Wall Rating — 1 HR. 1. Floor and Ceiling Runners — (Not shown) — Channel shaped runners, 3-5/8 in. deep (min), 1-1/4 in.
Learn Morenexrep jobs indeed; lilith in partners 8th house synastry
Learn More
Leave A Reply